Shutdown
CHANGEOVER TO EXTERNAL POWER
When parked at ramp:
Place external power switch on.
Select essential power and ac power to EXT PWR.
ENGINE SHUTDOWN
Operate engines at idle RPM for 1 minute before shutdown. Move start levers to CUTOFF, and check that EGT drops, indicating clean shutdown.
FLIGHT TERMINATION
Place the ground venturi switch to NORMAL after the first cabin door is open.
Turn off all cockpit lights excecpt dome and fluorescent lights.
Place DC METERS selector to ESS TR.
Place all engine bleed air switches to OPEN position.
Check radio switch off
Close both air conditioning pack switches after Secure Cockpit checklist completed
If APU is in use, let it run for approximately two minutes with no air load before shutdown.
After APU shutdown turn battery switch off.
Place EXTERNAL POWER selector to GRD SERVICE.